Available under Solimpeks logo Available under Motiontec Energy logo
Storage Tanks

Solitank

Hygienic instant hot water plus heating buffer in one tank

Capacities200 – 1,000 L
DHW coilAISI 316L stainless steel
Max pressure6 bar
Insulation50 mm PU

Tell us your project requirements and we will reply with pricing and lead time.

Overview

Solitank is a dual-purpose cylinder that works as a heating buffer and an instantaneous domestic hot water generator at the same time. The stored heating water surrounds a corrugated AISI 316L chrome-nickel stainless steel coil, and mains water passing through that coil is heated on demand instead of being stored, so the stagnant volumes that favour Legionella never build up. Five capacities from 200 to 1000 litres cover homes, hotels and light commercial buildings.

Because the same vessel doubles as a buffer tank, Solitank hydraulically separates the heat pump circuit from the heating circuit, absorbs surplus generation and covers sudden draw-offs without pushing the compressor into short cycling. Models up to 500 L use 50 mm polyurethane inside a static-painted galvanised jacket, while the 800 and 1000 L versions use 80 mm sponge insulation under an artificial-leather cover. Published heat loss runs from 74 W to 220 W.

The flexible corrugated coil delivers more than 50% extra performance compared with traditional pipe: turbulent flow keeps the surface clear of lime and residue, and the larger area transfers heat faster. AISI 316L stainless steel is suitable for drinking water and highly corrosion resistant, so no sacrificial anode rod is required and maintenance stays minimal. An optional electric heater can be added, and every model is rated to 6 bar and 95 °C.

Key features

  • Domestic hot water production and heating buffer duty in a single tank
  • Corrugated AISI 316L stainless steel coil heats mains water instantly and prevents Legionella formation
  • More than 50% extra heat transfer versus traditional pipe, with self-cleaning turbulent flow
  • Hydraulic separation between heat pump and heating circuits, protecting against short cycling
  • 50 mm polyurethane insulation (200-500 L) or 80 mm sponge insulation (800-1000 L)
  • No anode rod required; minimum maintenance
  • Optional electric heater support; 6 bar working pressure, 95 °C maximum temperature
  • Five capacities: 200, 300, 500, 800 and 1000 L

Applications

  • Residential domestic hot water
  • Apartment buildings
  • Hotels and guesthouses
  • Heat pump integration and buffering
  • Underfloor and radiator heating support
  • Light commercial hot water systems

Technical specifications

ParameterSolitank 200Solitank 300Solitank 500Solitank 800Solitank 1000
Energy efficiency classCCDEE
Heat loss (W)7485140195220
Tank volume (L)1702454608501030
Weight (kg)6785106165190
Dimensions H×D (mm)1200 × 5401750 × 5401700 × 7501850 × 10102150 × 1010
Max boiler water temp (°C)9595959595
Max working pressure (bar)66666
Insulation materialPolyurethanePolyurethanePolyurethaneSpongeSponge
Insulation thickness (mm)5050508080
Outer cylinderStatic painted galvanized sheetStatic painted galvanized sheetStatic painted galvanized sheetArtificial leatherArtificial leather
DHW coil water volume (L)121213.522.527.5
DHW coil surface area (m²)3.83.84.37.28.7
Coil max pressure (bar)66666
Feed water in/outG 1 1/4"G 1 1/4"G 2"G 2"G 2"
Underfloor heating in/outG 1 1/4"G 1 1/4"G 2"G 2"G 2"
Electric heaterG 1 1/4"G 1 1/4"G 2"G 2"G 2"
Domestic water in/outG 3/4"G 3/4"G 3/4"G 3/4"G 3/4"
SensorG 1/2"G 1/2"G 1/2"G 1/2"G 1/2"
EmptyingG 1/2"G 1/2"G 1/2"G 1/2"G 1/2"

Values are taken from the manufacturer's current catalogue and may change without notice. Please request the latest datasheet before final design.

Certifications

  • TSE (Turkish Standards Institution)
  • ISO 45001:2018
  • ISO 50001:2018
  • EN ISO 12100:2010

Related products

Planning a project? Let's size it together.

Send us your heating load, hot-water demand or pool volume and our engineers will propose a matching heat pump, tank and collector configuration.