One panel producing electricity and hot water together
Tell us your project requirements and we will reply with pricing and lead time.
The PV-T Excell hybrid panel produces electricity and usable heat from the same 2.7 m² of roof. A monocrystalline 144-cell module forms the front of the laminate while a copper thermal absorber bonded behind it recovers the heat the cells would otherwise waste. Because the integrated circuit cools the cells, electrical efficiency rises, so a single mounting area does two jobs instead of one.
The panel is rated at 590 Wp with 22.84% module efficiency, delivering 43.10 V and 13.69 A at maximum power under STC, with 51.72 V open circuit and 14.44 A short circuit; at NMOT the figures are 439 W, 39.9 V and 11.00 A. Solimpeks quotes a combined peak output of 1200 W per unit from Kiwa test report L0000435/B rev.02, and headline efficiencies of 22% electrical plus 43% thermal.The panel is rated at 590 Wp with 22.84% module efficiency, delivering 43.10 V and 13.69 A at maximum power under STC, with 51.72 V open circuit and 14.44 A short circuit; at NMOT the figures are 439 W, 39.9 V and 11.00 A. Motiontec Energy quotes a combined peak output of 1200 W per unit from Kiwa test report L0000435/B rev.02, and headline efficiencies of 22% electrical plus 43% thermal.
Mechanically the panel measures 2288 × 1195 × 60 mm and weighs 40 kg. Front glazing is 3.2 mm high-transmission, AR-coated, heat-strengthened glass over POE/EVA encapsulant and a KPF back sheet, framed in 35 mm anodised aluminium alloy so standard photovoltaic mounting hardware can be used. An IP68 junction box, 4 mm² solar cable and MC4 EVO2 / TS4 connectors match conventional PV wiring practice, with safety class II and a 15 A maximum series fuse.
The panel is offered in 540 W and 590 W versions; the technical table below refers to the PV-T Excell 590 W model. Please contact us for the 540 W datasheet.
| Parameter | Value |
|---|---|
| Product code | EXCELL PVT 590 |
| Panel dimensions | 2288 × 1195 × 60 mm |
| PV module dimensions | 2278 × 1134 × 35 mm (±0.1%) |
| Panel weight | 40 kg |
| PV module weight | 28 kg |
| Gross area | 2.7 m² |
| Nominal power | 590 W |
| Number of cells | 144 (6 × 24) |
| Solar cells | Monocrystalline |
| Glazing | PV glass |
| Front glass | 3.2 mm high-transmission, AR-coated, heat-strengthened glass |
| Encapsulant material | POE/EVA |
| Back glass | KPF type |
| Frame | 35 mm anodized aluminium alloy |
| Absorber surface (PV) | Mono |
| Absorber surface (thermal) | Copper |
| Electrical efficiency / thermal efficiency | 22% / 43% |
| Peak power per unit (Kiwa report L0000435/B rev.02) | 1200 W |
| STC peak power PMAX | 590 Wp |
| STC power tolerance range | 0~+5 W |
| STC maximum power voltage VMPP | 43.10 V |
| STC maximum power current IMPP | 13.69 A |
| STC open circuit voltage VOC | 51.72 V |
| STC short circuit current ISC | 14.44 A |
| Module efficiency | 22.84% |
| NMOT maximum power PMAX | 439 Wp |
| NMOT maximum power voltage VMPP | 39.9 V |
| NMOT maximum power current IMPP | 11.00 A |
| NMOT open circuit voltage VOC | 48.39 V |
| NMOT short circuit current ISC | 11.77 A |
| Safety class | II |
| Maximum over-current protection rating | 15 A |
| J-Box | IP 68 rated, 30 cm cable (optional 120 cm) |
| Cables | Photovoltaic technology cable 4.0 mm² |
| Connector | MC4 EVO2 / TS4 |
| STC test conditions | Irradiance 1000 W/m², cell temperature 25 °C, AM1.5 (measuring tolerance ±3%) |
| NMOT test conditions | Irradiance 800 W/m², ambient temperature 20 °C, wind speed 1 m/s |
Values are taken from the manufacturer's current catalogue and may change without notice. Please request the latest datasheet before final design.
Selective-coated flat plate collector, Solar Keymark certified
View details
Send us your heating load, hot-water demand or pool volume and our engineers will propose a matching heat pump, tank and collector configuration.